Drinking-water safety · full-process monitoring

Five-level protection
Keep drinking water safe from source to tap

Source warning, plant process, network distribution, secondary supply, and tap-end monitoring. Toxicity, physicochemical, and metal indicators put every stretch from intake to tap on screen. Process data feed the regulator platform to keep supply water safe.

Five-level protection full chain from source to tap Biological toxicity 15-minute comprehensive toxicity warning 0.001NTU High-resolution filtered-water turbidity Four-level warning blue / yellow / orange / red graded response
5 levelsSource · plant · network · secondary · tap
15 mincomprehensive toxicity result
0.001 NTUTurbidity resolution
≤1 minconventional indicator response
Finished water · WP-036 LIVE
Residual chlorine Cl₂ 0.62mg/L
Turbidity TURB 0.08NTU
pH pH 7.42
Comprehensive toxicity TOX 3.1%
Physicochemical 5 min / toxicity 60 min · 4G −68 dBm · all indicators in spec
USACORE TECHNOLOGY
·
MILANOINDUSTRIAL DESIGN
·
ZHUHAIMANUFACTURING
Overview

From intake to tap, one network all the way

Built around drinking-water safety: source warning, plant process, network distribution, secondary supply, and tap-end quality — a five-level chain with no blind spots.

The solution is deployed by grade at sources, plant intakes and outlets, process sections, network nodes, secondary-supply pump rooms, and tap ends. Toxicity analyzers, multi-parameter monitors, heavy-metal analyzers, and automatic samplers provide online coverage from intake to tap around the clock.

Full-process data feed the drinking-water safety platform, withanomaly warning, source tracing, and emergency action capability. Toxicity and metals at the front; physicochemical and disinfection indicators through treatment and distribution — a complete technical stack for drinking-water safety.

Five-Level Protection

Five field levels, one platform

Defense follows the water: five field levels, a sixth on the platform. Any abnormal stretch is found early and located fast.

01

Source-water warning

  • 24-hour online toxicity warning, sensitive to unknown pollutants
  • pH, DO, turbidity, conductivity, ammonia, COD, chlorophyll, and level together
  • Intake metals analysis and exceedance retention lock evidence
  • Deployed products: ZYS-DX01 toxicity analyzer + ZYS-1000A buoy station
02

Plant process monitoring

  • Inlet/outlet pH, turbidity, residual chlorine, conductivity, temperature
  • Sedimentation turbidity, filtered-water turbidity, and chlorination residual chlorine together
  • Data feed coagulation, sedimentation, filtration, and disinfection — and cut energy use
  • Deployed products: Floor-standing + wall-mounted multi-parameter monitors
03

Network distribution monitoring

  • See chlorine decay live to guide rechlorination and dispatch
  • Turbidity alarms catch bursts, flushing, and other quality swings
  • Quality with pressure and flow to calibrate the hydraulic model
  • Deployed products: Pole-mounted multi-parameter station (solar)
04

Secondary-supply control

  • Residual chlorine, turbidity, pH, ORP, and level for high-rise supply
  • Compact design for pump rooms and tank rooms, low retrofit cost
  • Control the last kilometer of supply and cut secondary-pollution risk
  • Deployed products: Wall-mount secondary-supply monitor
05

Tap-end quality monitoring

  • Residual chlorine, turbidity, pH, and temperature at the tap
  • Low-cost micro terminals for communities, schools, hospitals, and other tap ends
  • Stand up a point network fast for health supervision and public information
  • Deployed products: Compact multi-parameter terminal
06

Unified regulator platform

  • GIS overview of every point status and quality distribution
  • Blue / yellow / orange / red four-level warning, graded response
  • Locate the source on network topology to support emergency decisions
  • Connects to health, housing, and environmental platforms
Recommended Products

Five in-house lead products, placed by process step

Core products are chosen for each drinking-water step. Specify a single point, or a set from source + plant + network + secondary supply + tap end.

ZYS-DX01 Core source comprehensive-toxicity warning

Online biological toxicity analyzer

  • Based on the luminescent bacteria method, meeting ISO 11348 and GB/T 15441, showing acute comprehensive toxicity directly
  • Sensitive to unknown pollutants, Results in 15–60 minutes, spotting pollution risk before conventional indicators
  • Inhibition 0–100%, resolution 1%, 24-hour online duty, auto alarm on anomaly
  • Linked with physicochemical and metal indicators as the first source gate
Applications

Centralized source warning · plant intake gate · sudden-pollution emergency monitoring

ZXcm-500 Intake metal QC and retention evidence

Online heavy-metal analyzer

  • Covers lead, cadmium, arsenic, chromium, and other metals, µg-level detection limit, meets drinking-water limits
  • Linked with the ZYAT-610 automatic sampler, auto retain on exceedance, locking evidence for review
  • Continuous online monitoring, without the lag and gaps of grab samples
  • Factor sets can follow source-specific pollutants
Applications

Plant-intake QC · source monitoring · tracing and evidence

Multi-parameter series Floor / wall / pole / compact four forms

Multi-parameter online monitor

  • Modular pH, turbidity, residual chlorine, conductivity, temperature, ORP, 8 channelsFlexible multi-point monitoring
  • TurbidityResolution 0.001 NTU, meeting high-accuracy needs for filtered and finished water
  • Stable residual-chlorine monitoring for chlorination optimization and energy saving
  • Response ≤1 min; instrument IP54 / sensor IP68, indoor and outdoor
Applications

Plant in/out · sedimentation / filtered water / chlorination · network nodes · tap ends

ZYS-1000A Preferred for open-water in-situ source monitoring

Buoy water-quality monitoring system

  • HDPE float, Wave- and corrosion-resistant, can stay on reservoir and lake sources
  • Accepts pH, DO, conductivity, turbidity, ammonia, COD, chlorophyll-a sensors; probes IP68
  • Solar + lithium storage, No shore cabling, keeps working in rain
  • GPS / BeiDou, beacon light, and attitude monitoring, with drift alarms
Applications

In-situ source monitoring · reservoir grid · algae and eutrophication warning

Secondary / tap-end dedicated A compact terminal for the last kilometer of supply

Secondary-supply and tap-end terminals

  • Secondary-supply model for residual chlorine, turbidity, pH, ORP, andLevel, quality and volume control for pump rooms and tanks
  • Tap-end terminals monitor residual chlorine, turbidity, pH, temperature, Low-cost compact design, for community, school, and hospital points
  • Wall mount, no civil rebuild — add to old pump rooms and existing networks quickly
  • Plant and network points share one platform; tap-end anomalies can be traced upstream
Applications

High-rise secondary pump rooms · community tanks · school/hospital taps · public quality boards

System Architecture

Three network layers, five steps on one platform

The sensing layer is laid out by process step. Data return encrypted through the network layer. The drinking-water safety platform handles warning, dispatch, and public information.

Layer 03 · Platform Drinking-water safety platform
Safety warning Process optimization Network analysis Emergency command Reports Public information GIS overview
Unified data access
Layer 02 · Network Network layer
4G / fiber / NB-IoT Resume on disconnect Data encryption Edge gateway
Encrypted backhaul
Layer 01 · Perception Five-level sensing layer
Source warning: toxicity / buoy station Plant process: five parameters / metals Network: residual chlorine & turbidity / pressure & flow Secondary supply: quality / level Tap end: compact five-parameter station Automatic sampler / retention unit
Deployment Reference

Select by process step, standard product sets

Ready product sets, parameters, and value notes for seven key drinking-water steps.

Monitoring step
Featured products
Parameters
Key value
Monitoring stepSource-water warning
Featured productsZYS-DX01 Toxicity analyzer + ZYS-1000A Buoy station
ParametersComprehensive toxicity, pH, DO, turbidity, conductivity, ammonia, COD, chlorophyll, level
Key valueLuminescent bacteria method for comprehensive toxicity, results in 15 minutes, 24-hour online early warning
Monitoring stepIntake QC
Featured productsZXcm-500 Heavy-metal analyzer + ZYAT-610 Sampler
ParametersLead, cadmium, arsenic, chromium, and exceedance retention
Key valueµg-level detection limit, auto retain on exceedance, locking evidence
Monitoring stepPlant inlet/outlet
Featured productsFloor-standing multi-parameter monitor
ParameterspH, turbidity, residual chlorine, conductivity, temperature
Key value0.001NTU High-resolution turbidity to hold finished-water quality
Monitoring stepPlant process section
Featured productsWall-mounted multi-parameter monitor
ParametersSedimentation turbidity, filtered-water turbidity, chlorination residual chlorine, pH
Key value8 channelsFlexible mix, multi-point monitoring, process guidance
Monitoring stepKey network nodes
Featured productsPole-mounted multi-parameter station
ParametersResidual chlorine, turbidity, pH, pressure, flow
Key valueSolar power, stand up points fast and watch network quality
Monitoring stepSecondary supply
Featured productsWall-mount secondary-supply monitor
ParametersResidual chlorine, turbidity, pH, ORP, level
Key valueCompact fit for pump rooms, to control supplylast kilometer
Monitoring stepTap-end monitoring
Featured productsCompact multi-parameter terminal
ParametersResidual chlorine, turbidity, pH, temperature
Key valueLow-cost compact design, for community, school, and hospital tap ends
Why This Works

Five core strengths, built for drinking-water safety

From coverage and warning time to process accuracy, network control, and platform dispatch — each layer is built for real supply duty.

Full-process coverage · no blind spots
From source intake to the tap, every key node is covered Physicochemical + toxicity + metals + disinfection — multi-dimension control Quality and hydraulics together to calibrate the network model
Toxicity early warning · risk seen early
Based on luminescent bacteria, meets ISO 11348 and GB/T 15441 Direct acute comprehensive toxicity, sensitive to unknown pollutants 15–60 minutes results, spotting pollution risk before conventional indicators
High-accuracy process monitoring · better finished water
Turbidity resolution 0.001NTU, meeting high-accuracy filtered-water needs Stable residual-chlorine monitoring for chlorination optimization and energy saving Multi-parameter analysis to guide coagulation, sedimentation, and disinfection
Live network control · less secondary pollution
Live chlorine-decay monitoring to guide rechlorination and dispatch Turbidity alarms catch bursts, flushing, and other quality swings Secondary-supply quality and level for high-rise safety
One platform for dispatch · faster emergency response
GIS overview of every point status and quality distribution Blue / yellow / orange / redFour-level warning, graded response and action Locate the source on network topology to support emergency decisions
Platform Features

Platform functions, from monitoring to closed loop

Live monitoring, safety warning, process and network analysis, emergency command, reports, and O&M — one platform for drinking-water safety.

Live monitoring and safety warning

  • Live monitoringLive quality and hydraulic parameters at every node, GIS overview
  • Safety warningToxicity, metals, and conventional exceedance warnings, four-level push

Process optimization and network analysis

  • Process optimizationOnline data for coagulation, sedimentation, filtration, disinfection, and chlorination
  • Network analysisChlorine decay, water age, quality trends, and dispatch advice

Emergency command and source tracing

  • Emergency commandEvent tracing on network topology to support the response
  • Report managementAuto daily / monthly / yearly reports for regulators and public quality information

Equipment O&M and data connection

  • Equipment O&MDevice status, fault diagnosis, reagent remaining, and maintenance reminders
  • Data connectionConnects to health, housing, and environmental platforms with open interfaces
Technical Specs

Typical specifications

Typical figures for representative products. Ranges and factors can be extended to the site.

Turbidity0–20 NTU · ±3% FS · resolution 0.001 NTU
Residual chlorine0 ~ 20 mg/L · ±2%FS
pH0 ~ 14 pH · ±0.1 pH
Biological toxicity0–100% inhibition · resolution 1%
Heavy metalsµg-level detection · meets drinking-water limits
Response time≤1 min (conventional indicators)
Ingress protectionInstrument IP54 / sensor IP68
Communications4G / fiber / NB-IoT
Power supplyAC 220 V / solar / lithium battery
Data connectionStandard protocols to health / housing / environmental platforms
Use Cases

Typical applications

One five-level chain covering eight high-frequency scenes from source warning to tap-end public boards.

Centralized drinking-water source warning

Toxicity + multi-parameter + metals — find risk early and act early.

Waterworks inlet/outlet and process monitoring

Inlet, outlet, and process sections online together to hold finished-water quality and guide the process.

Urban supply-network quality monitoring

Live residual chlorine, turbidity, pressure, and flow through distribution.

High-rise secondary-supply quality and level

Pump-room and tank quality plus level — the last kilometer of supply.

Tap-end monitoring at schools, hospitals, and key sites

Micro terminals sample tap-end quality so key sites can see the water is safe.

Drinking-water hygiene supervision online

Traceable data and auto reports for health supervision and public information.

Supply security for major events

Denser temporary points and full online watch during major events.

Sudden water-pollution emergency monitoring

Lock the affected area and source fast, with four-level emergency action.

Get Your Plan

Customize your
Drinking-water safety solution

Tell us supply scale, point layout, and parameters. An engineer will return a selection list, configuration, and quote within 24 hours.

Phone139 2696 7285
AddressNo. 40, Jinfeng West Road, High-tech Zone, Zhuhai, Guangdong