Heavy Metal Online Water Quality Analyzer · M200-Xcm5 Series 

Ten Types of Heavy Metals,
One Online Precise Monitor

M200-Xcm5 Series Heavy Metal Online Water Quality Analyzer adopts photoelectric metering, high-temperature high-pressure digestion, and integrated digestion-colorimetry technology. It can online monitor heavy metal factors including total manganese, total iron, total lead, total zinc, total arsenic, total nickel, total chromium, total cadmium, total copper, and hexavalent chromium. Accurate measurement, low detection limit, high reliability, compliant with national environmental standards, and reagents can be self-configured according to national standards.

10Heavy Metal Factors
25minMin. Cycle
±10%Accuracy
3yr+Historical Data
RemoteControl & O&M
Heavy Metal Online Water Quality Analyzer
Key Highlights

Integrated Digestion-Colorimetry, Accurate and Worry-Free

Three things matter for heavy metal online monitoring — measurement accuracy, maintenance hassle, and remote management capability. Photoelectric metering + light source self-calibration ensure precision; waste-wash separation + self-diagnosis reduce costs; integrated multi-indicator software lets you switch between different pollutants anytime.

Turbidity & Color Anti-Interference

Turbidity and color anti-interference design, stable readings even for complex water samples.

Wash-Waste Separation · Reagent Saving

Low reagent consumption, less waste liquid — wash-waste separation + reagent saving, low operating cost.

Self-Diagnosis · Auto Clean & Calibrate

Intelligent fault self-diagnosis + automatic cleaning, automatic calibration, low failure rate, easy maintenance.

Light Source Self-Calibration

Unique light source self-calibration avoids light decay effects and ensures high measurement accuracy.

Power-Fail Protection · 3+ Year History

Power-fail protection design, reliable data storage, saves 3+ years of historical data.

Remote Control O&M

Equipped with remote control function, central control can operate the instrument for remote maintenance.

Specifications

M200-Xcm5 · Technical Specifications

Method basis depends on the measured factor; range grading, accuracy, and cycle are as follows. Two models available (3rd gen / 4th gen), can be directly incorporated into comparison sheets.

Method BasisDepends on measurement factor
Measurement range0–20 mg/L (graded 0.1–5 / 0.5–10 / 1–20)
Accuracy≤ ±10% or ≤ ±0.2 mg/L
Repeatability≤ ±5%
Measurement CycleMin. 25 minutes
Sampling CycleHourly / equal interval 5–99min / external trigger
Calibration Cycle≤ 24 hours
Maintenance Cycle~once per month · ~30min each time
Digestion MethodHigh-temp high-pressure digestion · integrated colorimetry
Output2 ch RS-232 · 1 ch 4~20mA
EnvironmentIndoor +5~28℃ · Humidity ≤90% (non-condensing)
Power SupplyAC220V±10% · 50Hz±10% · 5A
Dimensions3rd gen 512×427×1480 · 4th gen 330×285×510 mm
OtherAbnormal alarm · data preserved on power failure
Heavy Metal Online Analyzer ONLINE
Total Pb mg/L0.008
Total Cd mg/L0.003
Total Cr mg/L0.041
Hexavalent Cr mg/L0.012
Total As mg/L0.006
Total Cu mg/L0.15
M200-Xcm5 · RS-232 / Remote Control
Live Analysis

Integrated Digestion-Colorimetry,
Online Reading & Reporting

High-temperature high-pressure digestion and colorimetry integration; automatic measurement on the hour or at equal intervals, over-limit alarm. Integrated multi-indicator analysis software can switch to measure different pollutants anytime. Data is reported via RS-232, supporting remote central control and maintenance.

  • DigestionHigh-temp high-pressure digestion · integrated colorimetry
  • CalibrationAuto clean & calibrate · light source self-calibration
  • ReliablePower-fail protection · 3+ years data preserved
  • O&MRemote control · multi-indicator software switching
Monitored Factors

One Instrument, Ten Types of Heavy Metals

Switch software on the same analyzer to measure different heavy metal factors. Range 0–20 mg/L with grading; reagents can be self-configured per national standards. Filter by category to quickly locate the desired factor.

MnPhotoelectric Colorimetry

Total Manganese

Total Manganese
Common heavy metal · 0–20mg/L graded
FePhotoelectric Colorimetry

Total Iron

Total Iron
Common heavy metal · 0–20mg/L graded
ZnPhotoelectric Colorimetry

Total Zinc

Total Zinc
Common heavy metal · 0–20mg/L graded
CuPhotoelectric Colorimetry

Total Copper

Total Copper
Common heavy metal · 0–20mg/L graded
NiPhotoelectric Colorimetry

Total Nickel

Total Nickel
Common heavy metal · 0–20mg/L graded
PbPhotoelectric Colorimetry

Total Lead

Total Lead
Priority toxic factor · low detection limit
AsPhotoelectric Colorimetry

Total Arsenic

Total Arsenic
Priority toxic factor · low detection limit
CdPhotoelectric Colorimetry

Total Cadmium

Total Cadmium
Priority toxic factor · low detection limit
CrPhotoelectric Colorimetry

Total Chromium

Total Chromium
Priority toxic factor · low detection limit
Cr⁶⁺Photoelectric Colorimetry

Hexavalent Chromium

Hexavalent Chromium
Priority toxic factor · dedicated monitoring
Options & Add-ons

Optional Extensions, Complete Setup

From sampling pretreatment, national standard reagents to cloud platform remote control — freely select based on site conditions, fully equipped and stable online in one go.

Sampling

Sampling Pretreatment

Sampling Unit

Filtration / turbidity removal pretreatment, protects optical path for longer life.

Reagent

National Standard Reagent Kit

Reagent Kit

Configured per national standards, self-preparable with controllable costs.

Maintenance

Auto-Cleaning Unit

Auto-Cleaning

Automatic colorimetric cell cleaning, reduces manual maintenance.

Thermostat

Thermostatic Cabinet

Thermostatic Cabinet

Indoor constant temperature environment, ensures stable readings.

Data

Data Logger · DTU

Data Logger

RS-232 to network, data directly transmitted to platform.

Platform

Remote Central Control Platform

Cloud Platform

Remote control O&M, alarms, reports — all managed in one place.

Power

UPS Backup Power

UPS Backup

Power-fail endurance, data and operation uninterrupted.

Software

Multi-Indicator Software Modules

Analysis Modules

Integrated multi-indicator analysis, switch pollutants anytime.

Applications

Watching Every Heavy Metal Discharge Point

From electroplating and metallurgy to wastewater plants, from industrial outlets to water sources — online monitoring of heavy metal factors, immediate alarm on anomalies, and remote controllable operation.

Electroplating WastewaterElectroplating
Metallurgy & MiningMetallurgy & Mining
Industrial Park OutletIndustrial Outlet
Municipal WWTPWWTP
Surface Water · SourceSurface & Source
Electronics / PCBElectronics / PCB
Tannery / LeatherTannery
Chemical / PharmaChemical / Pharma
Contaminated SiteContaminated Site
Get In Touch

Equip Your Outlet
With a Heavy Metal Analyzer

Tell us which heavy metal factors you need to monitor, water quality, and installation environment. We will provide model selection (3rd gen / 4th gen) and reagent / cycle configuration lists — methods and ranges are selected by factor.

Phone139 2696 7285
Websitewww.wiow.net
AddressNo. 40 Jinfeng West Road, (National) High-tech Zone, Zhuhai, Guangdong Province